Myson 15-10 Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
Slim-Line Fan Convector
ISO 9002
Side View
6
11
/16"
3
/4"
2"
3
1
/4"
6
7
/8"
5"
1
7
/8"
1
3
/8"
Minimum space
required (floor to
bottom of Slim-Line)
Centerlines of pipe entry
MODEL FLOW RATE FAN SPEED AIR DELIVERY
#
GPM
CFM
5,663 6,657 7,661 8,664 9,668 10,572 11,678 12,680 13,684 14,687
4,881 5,887 6,745 7,651 8,559 9,567 10,374 11,281 12,186 13,096
4,207 5,018 5,829 6,639 7,450 8,261 9,072 9,883 10,694 11,504
7,404 8,719 10,034 11,349 12,663 13,978 15,293 16,608 17,923 19,237
6,457 7,646 8,831 10,023 11,411 12,399 13,588 14,776 16,280 17,153
5,510 6,572 7,634 8,696 9,758 10,820 11,882 12,944 14,005 15,068
SL 16 1.0 Boost 186
Medium 127
Low 97
SL 16 3.0 Boost 186
Medium 127
Low 97
*For output at these water temperatures, optional 107°F low temperature cut-off required.
ENTERING WATER TEMPERATURE (°F)
120* 130* 140 150 160 170 180 190 200 210
MODEL UNIT WEIGHT
# WEIGHT PACKED
FAN CONVECTOR COMPARISON @ 180°F WATER TEMP
FRICTION LOSS
(HEAD)
UNIT WEIGHT (LBS)
SL 16 1.0 Boost 22 ft 52 sq ft
Medium 20 ft 46 sq ft
Low 17 ft 40 sq ft
SL 16 3.0 Boost 29 ft 68 sq ft
Medium 26 ft 60 sq ft
Low 23 ft 53 sq ft
FLOW RATE FT WG
GPM
SL 16 35 38
MODEL FLOW RATE FAN SPEED BASEBOARD C.I. RADIATORS
#GPM
(525 BTU/FT) (225 BTU/SQ FT)
0.5 0.66
1.0 1.84
1.5 3.81
2.0 5.81
SLIM-LINE FAN CONVECTOR — BTU/HR HEAT OUTPUT — ENTERING AIR @ 65°F
Front View
15
9
/16"
31
7
/8"
2
5
/16"
C
L
Centerline of pipe entry
MYSON reserves the right to make changes or improvements to
our products which may affect these specifications.
Fan Convector from MYSON
Slim-Line
TM
SLIM-LINE FAN CONVECTOR SPECIFICATIONS – Engineered to be efficient.
Controls... Units have a three-speed
Boost/Medium/Low fan switch and built-in
thermostat. All models have low-limit
thermostats which close at 129°F and
reopen at 109°F (±7°F).
Construction... The chassis is manufactured
from zinc-coated painted steel.
Tamper-Proof Controls Cover... All units
include a tamper-proof controls cover
which conceals all electrical connections
from unauthorized usage.
Warranty... MYSON offers a full ten year
warranty on the heat exchanger and a full
three year warranty on the fan motor.
10 Myson, Inc. • 800-698-9690 • www.MysonInc.com
NOTE: For surface
mounting application only.
NOTE: For proper sizing, use the rating at Medium or Low speeds.
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16

Kommentare zu diesen Handbüchern

Keine Kommentare